Back to Top

1
Hi, Guest!
  • BENTLY NEVADA
  • 3500/61 Specifics - Bently Nevada - Temperature Module

3500/61 Specifics - Bently Nevada - Temperature Module

Update Terakhir
:
26 / 01 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Kirimlah inquiry Anda ke email kami : [email protected], dengan senang hati kami akan melayani anda hingga anda mendapatkan produk-produk yang dibutuhkan. Kami akan berusaha sebaik-baiknya untuk memberikan pelayanan terbaik kami, baik dalam hal customer service, bantuan teknis, pricing maupun delivery time yang tepat waktu .

Detail 3500/61 Specifics - Bently Nevada - Temperature Module

3500/61 - Specifics
Part Numbers:
163179-02 3500/61 Temperature Monitor (with recorders)
133819-02 3500/61 RTD/TC Non-Isolated I/O Module Internal Terminations
133827-02 3500/61 RTD/TC Non-Isolated I/O Module External Terminations
133835-02 3500/61 TC Isolated I/O Module Internal Terminations
133843-02 3500/61 TC Isolated I/O Module External Terminations
133892-01 3500/61 Recorder Output External Termination Block (Terminal Strip connectors)
133900-01 3500/61 Recorder Output External Termination Block (Euro Style connectors)
136711-02 3500/61 RTD/TC I/O Module with Internal Barriers and Internal Terminations. (Not Isolated)

(6) Channels of Temperature Monitoring
Ttemperature Inputs: Resistance Temperature Detector (RTD) and Thermocouple (TC)
Recorder Outputs for each Channel (3500/61)
RTD/TC Non-Isolated or TC Isolated Versions.


The GE / Bently Nevada 3500/60 and 3500/61 Series Temperature Monitors Modules provide six channels, emperature monitoring and accept both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs. The modules condition these inputs and compare them against user-programmable alarm setpoints. The 3500/60 and 3500/61 provide identical functionality except that the 3500/61 provides recorder outputs for each of its six channels while the 3500/60 does not.
The user programs the modules to perform either RTD or TC temperature measurements using the 3500 Rack Configuration Software. Different I/O modules are available in RTD/TC non-isolated or TC isolated versions. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference.


When used in a Triple Modular Redundant (TMR) configuration, temperature monitors must be installed adjacent to each other in groups of three. When used in this configuration, the system employs two types of voting to ensure accurate operation and to avoid single-point failures.

#Bently Nevada
#Temperature Module
#3500/61
#Specifics

Tampilkan Lebih Banyak
Kontak Kami